What is the Difference Between C8 and C18 Column in HPLC

What is the Difference Between C8 and C18 Column in HPLC

The main difference between C8 and C18 column in HPLC is that the C8 column contains octyl carbon chain (C8)-bonded silica as the stationary phase, but the C18 column contains octadecyl carbon chain (C18)-bonded silica.

  1. Which column is more polar c8 or C18?
  2. What is difference between ODS and C18 column?
  3. Why we use C18 column in HPLC?
  4. How do I choose the right column for HPLC?
  5. What is polar and nonpolar?
  6. Is C18 Polar?
  7. What is ODS and BDS column?
  8. Why pH is important in HPLC?
  9. What is the tailing factor?
  10. Which column is used in HPLC?
  11. What is inside HPLC column?
  12. What is pore size in column?

Which column is more polar c8 or C18?

C18 has 18 carbon atoms while C8 has only 8 carbon atoms. C18 has a longer carbon chain, but C8 has a shorter one. C18 has higher retention while C8 has shorter retention. C18 has higher hydrophobicity, but C8 has a lower hydrophobicity.
...
Follow Pharmaguideline.

LikeFollow
FollowInstall
Join

What is difference between ODS and C18 column?

The AQ type C18 column, such the ODS-B, has an end-capping that reduces phase collapse greatly, so it can be run in 100% water if needed. The ODS-A column has a more typical hydrophobic end-capping. ... Compounds that require more than 50% organic to elute will be less affected by the hydrophilic end-capping on the ODS-B.

Why we use C18 column in HPLC?

C18 columns are HPLC (high performance liquid chromatography) columns that use a C18 substance as the stationary phase. C18 HPLC columns are used in environmental sciences and chemical analysis, as well as industries such as pharmaceutical and environmental sciences, to analyze individual parts of chemical mixtures.

How do I choose the right column for HPLC?

Choose a column packing with small pore size (60-80Å) if the solute molecular weight is less than about 2000 - 4000 Daltons. Otherwise, use a column packing with 300Å pore size. Figures 1 and 2 shows the effects of pore size on peak width and sample load.

What is polar and nonpolar?

Nonpolar bonds form between two atoms that share their electrons equally. Polar bonds form when two bonded atoms share electrons unequally.

Is C18 Polar?

A C18 column is an example of a "reverse phase" column. Reverse phase columns are often used with more polar solvents such as water, methanol or acetonitrile. The stationary phase is a nonpolar hydrocarbon, whereas the mobile phase is a polar liquid.

What is ODS and BDS column?

ODS and BDS are two columns used for reverse-phase chromatography. The key difference between ODS and BDS column is that ODS column contains free –OH functional groups, whereas BDS column contains deactivated –OH groups. Moreover, ODS columns have high peak tailing while BDS columns are designed to reduce peak tailing.

Why pH is important in HPLC?

When samples contain ionisable compounds, mobile phase pH can be one of the most important variables in the control of retention in a reversed‑phase HPLC (RP-HPLC) separation. ... Since most compounds analysed by RP-HPLC contain one or more acidic or basic functional groups, most mobile phases require pH control.

What is the tailing factor?

The tailing factor is a measure of peak tailing. It is defined as the distance from the front slope of the peak to the back slope divided by twice the distance from the center line of the peak to the front slope, with all measurements made at 5% of the maximum peak height.

Which column is used in HPLC?

The reversed-phase HPLC column is the most versatile and commonly used column type and can be used for a wide range of different types of analytes. Normal-phase HPLC columns have polar packing. The mobile phase is nonpolar and therefore usually an organic solvent such as hexane or methylene chloride.

What is inside HPLC column?

A monolithic HPLC column, or monolithic column, is a column used in high-performance liquid chromatography (HPLC). ... In contrast, most HPLC configurations use particulate packed columns; in these configurations, tiny beads of an inert substance, typically a modified silica, are used inside the column.

What is pore size in column?

The surface area of the particle is inversely proportional to the pore diameter; therefore, a 3 mm particle with a 120 nm pore diameter will have more than twice the surface area of a 3µm particle with a 300 nm pore diameter. There are a number of pore diameters used by manufacturers to control retention.

Difference Between Apple Juice and Apple Cider
Apple cider is made from apples that are washed, cut and ground into an "apple mash" similar to applesauce. ... On the other hand, apple juice undergo...
Difference Between Organic and Inorganic Compounds
The primary difference that lies between these organic compounds and inorganic compounds is that organic compounds always have a carbon atom while mos...
Difference Between Fundamental and Realized Niche
Fundamental niche is the entire set of conditions under which an animal (population, species) can survive and reproduce itself. Realized niche is the ...